AGIO01
Remote I/O — 16 in / 8 out
Central-i remote I/O module. Every input and output is updated at the controller each 16 kHz sampling cycle (~61 µs) — a sensor wired to an AGIO reads exactly like one wired to the axis amplifier itself. Outputs sink up to 500 mA or source 300 mA, enough to drive most relays and solenoids directly.
DownloadsDatasheets & manuals
Specifications
| Communication | Central-i |
| Power Supply | 9 to 36VDC |
| Sampling Rate | 16 KHz |
| Differential Bi-Directional I/O | 3 |
| Isolated inputs | 16 |
| Isolated outputs | 8 |
| Analog inputs | 4 (16-bit resolution) |
| Analog outputs | 0 |
More in Central-i Series


AGM800
Central-i master controller — 8 axes

AGA101
DC remote amplifier — 90 VDC

AGA102
DC remote amplifier — 48 VDC compact

AGA103
DC remote amplifier — 48 VDC miniature
PRODUCT PHOTO
AGA110
DC remote amplifier — high voltage
PRODUCT PHOTO
AGLA101
Linear remote amplifier

AGL101
Third-party drive adapter

AGL102
Third-party drive adapter — lite
PRODUCT PHOTO
AGL103
Third-party drive adapter

AGIO02
Remote I/O — 32 in / 16 out